 PRODIS-TDC Digital Process Meter for Time-of-Flight Sensors
* For Sensors with pulse output: * Automatic sensor parameter upload at power-on - no calibration necessary * Integrated sensor supply * 6-digit LED display * RS-232 interface * Optional 4 comparator outputs * Easy programming
Description
PRODIS-TDC displays measurement values of magnetostrictive position sensors, programmable scaling is provided to display units like mm or inch. The request signal will be sent to the sensor periodically. The time between the start pulse and the stop pulse will be counted by a high-resolution time-digital-converter (TDC). When used with POSICHRON sensors the calibration parameters of the sensor will be uploaded to the meter at power-on. This avoids a calibration when the sensor has been changed. A tare function or programming lock can be activated with two control terminals. Sensor excitation is supplied from the meter. Optional comparator functions with 4 NPN open-collector outputs are available, additional 2 of them have relay output.
Display 6 - digit, 7-segment-LED, 14 mm high, decimal point programmable 24 V DC 10%/150 mA, residual ripple 1%ss 85-250 V AC/180 mA max. 1 ... 5 ms, adjustable 24 V DC/300 mA or 5 V DC/500 mA INIT, INIT (RS422) STSP, (RS422) 2 control inputs, active low 250 V AC/5 A, 30 V DC/5 A 24 V max./50 m A to GND Terminal strip 12-pole, excitation 3-pole -10 ... +40 C -20 ... +85 C 24 VDC: 250 g approx., 230 VAC: 400 g approx. Front IP60, rear IP40 Max. 95% R.H, non condensing Directive 73/23/EWG: DIN EN 61010:1994-03 Directive 89/336/EWG
Specifications
Excitation voltage/current Sampling rate Sensor excitation Start pulse input Measurement pulse input Control inputs Comparator outputs (option) Relay NPN Connection Operating temperature Storage temperature Weight Protection class Humidity Safety of equipment Electromagnetic compatibility
Order code PRODIS-TDC
Model Name Excitation Voltage 24VDC = 24 V DC 230VAC = 85...250 V AC Comparator (option) REL2
PD-TDC
Order example: PD - TDC - 24VDC
50 CAT-PC-E-04 Tel.: +49-8123-986-0 Fax: +49-8123-986-500 www.asm-sensor.com ASM GmbH
PRODIS-TDC Digital Process Meter for Time-of-Flight Sensors
Programmable Parameters / value range
Divisor, Multiplier, offset, limit values Other programmable parameters 0 up to 999999 Wave speed, average function, edge evaluation, use with several magnets, difference evaluation, decimal point position, display brightness
Signals
Wiring basic equipment
Sensor excitation +UB Sensor excitation 0 V (GND) Control input terminal1, active low Control input terminal2, active low Not used INIT output request pulse INIT output request pulse STSP input measurement pulse STSP input measurement pulse Do not connect! GND PD-TDC-24VDC Excitation +24 V Excitation 0 V (GND) PD-TDC-230VAC Excitation Protective ground
Connector X1 Pin no. 1 2 3 4 5/6 7 8 9 10 11 12
Connector X2 Pin no.
13 14
13, 15 14
5 .......1 RS-232 1 ................................12 13 14 15
PD-TDC-24VDC Rear view without comparator outputs
X1 X2 13 14 15
PD-TDC-230VAC
X1 X2
Level
RS-232: 8 V, galvanically isolated 1 startbit, 8 data bits, 1 stopbit, no parity 9600 Baud Connector X3 Pin no. 17 16 18 DSUB Pin no. 2 3 5
RS-232 interface
Data format Transmission rate Signals TxD RxD GND
ASM GmbH
Tel.: +49-8123-986-0 Fax: +49-8123-986-500 www.asm-sensor.com
CAT-PC-E-04
51
PRODIS-TDC Digital Process Meter for Time-of-Flight Sensors
30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
Rear view with comparator outputs
X3 X4
RS-232
Comparator
Comparator function (option)
Comparator 1
Comparator output NPN Connector X3 collector pin no. NPN1 20
Relay Relay 1 NO NC Common Relay2 NO NC Common
Connector X4 pin no. 25 27 26
LED LED1
Comparator 2
NPN2
21
LED2 28 30 29
Comparator 3 Comparator 4
NPN3 NPN4 NPN GND NPN UB (+24V)
22 23 24 19
Signals
Sensor circuit
Cable
PRODIS-TDC
PRODIS-TDC generates a request pulse via the INIT line. The position sensor responds with a START and a STOP signal. Position value x = t(x) * vs To calculate the position value the time interval t(x) must be multiplicated with the conversion factor vs on the type label. When ASM POSICHRONa sensors are used the conversion factor vs will be uploaded at power-on.
52
CAT-PC-E-04
Tel.: +49-8123-986-0 Fax: +49-8123-986-500 www.asm-sensor.com
ASM GmbH
PRODIS-TDC Digital Process Meter for Time-of-Flight Sensors
Outline drawing
LED1 LED2
Control panel cutout acc. to DIN 43700
PD - TDC - 24VDC
PD - TDC - 230VAC
Dimensions informative only For guaranteed dimensions consult factory!
ASM GmbH CAT-PC-E-04 53
Tel.: +49-8123-986-0 Fax: +49-8123-986-500 www.asm-sensor.com


▲Up To Search▲   

 
Price & Availability of PD-TDC-230VAC

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X